Probes

Active Voltage Probes

Engineers must commonly probe high-frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. Active voltage probes feature both high input R and low input C to reduce circuit loading across the entire probe/oscilloscope bandwidth. With low circuit loading, and a form factor that allows probing in confined areas, the active voltage probe becomes the everyday probe for all different types of signals and connection points.
Active Voltage Probes

Engineers must commonly probe high-frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. Active voltage probes feature both high input R and low input C to reduce circuit loading across the entire probe/oscilloscope bandwidth. With low circuit loading, and a form factor that allows probing in confined areas, the active voltage probe becomes the everyday probe for all different types of signals and connection points.

Overview

ZS Series High Impedance Active Probes
The ZS Series probes provide high impedance and an extensive set of probe tips and ground accessories to handle a wide range of probing scenarios. The high 1 MΩ input resistance and low 0.9 pF input capacitance means this probe is ideal for all frequencies. The ZS Series probes provide full system bandwidth with all Teledyne LeCroy oscilloscopes with bandwidths of 4 GHz and lower.

 

Model Bandwidth Input R Input C Dynamic Range OffsetRange Interface
ZS1000 1 GHz 1 MΩ 0.9 pF ± 8 V NA ProBus
ZS1500 1.5 GHz 1 MΩ 0.9 pF ± 8 V ± 12 V ProBus
ZS2500 2.5 GHz 1 MΩ 0.9 pF ± 8 V ± 12 V ProBus
ZS4000 4 GHz 1 MΩ 0.6 pF ± 8 V ± 12 V ProBus

Current Probes

Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
Current Probes

Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.

Overview

Current Probes
  • CP030 - 30A, 50MHz Current Probe
  • CP030A - 30A, 50MHz High Sensitivity Current Probe
  • CP031 - 30A, 100MHz Current Probe
  • CP031A - 30A, 100MHz High Sensitivity Current Probe
  • AP015 - 30 A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse Limited Availability
  • CP150 - 150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse
  • CP500 - 500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse
  • DCS015 - Deskew Calibration Source for AP015

Differential Amplifiers

Differential amplifiers are intended to act as signal conditioning preamplifiers for oscilloscopes and network and spectrum analyzers, providing differential measurement capability to instruments having only a single-ended input. The -PR2 version of each amplifier is a dual channel unit. The DXC series differential input cables are matched to the characteristics of the amplifier.
Differential Amplifiers

Differential amplifiers are intended to act as signal conditioning preamplifiers for oscilloscopes and network and spectrum analyzers, providing differential measurement capability to instruments having only a single-ended input. The -PR2 version of each amplifier is a dual channel unit. The DXC series differential input cables are matched to the characteristics of the amplifier.

Overview

Differential amplifiers are intended to act as signal conditioning preamplifiers for oscilloscopes and network and spectrum analyzers, providing differential measurement capability to instruments having only a single-ended input. The "-PR2" version of each amplifier is a dual channel unit. The DXC series differential input cables are matched to the characteristics of the amplifier.

Differential Probes (<= 1.5 GHz)

Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point
Differential Probes (<= 1.5 GHz)

Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point

Product

Differential Probes (<= 1.5 GHz)
  • AP033 - 500 MHz Differential Probe
  • ZD1000 - 1 GHz, 1.0 pF Active Differential Probe, ±8 V
  • ZD1500 - 1.5 GHz, 1.0 pF Active Differential Probe, ±8 V
  • ZD200 - 200 MHz, 3.5 pF, 1 MOhm Active Differential Probe, ±20 V
  • ZD500 - 500 MHz, 1.0 pF Active Differential Probe, ±8 V

Differential Probes (4-6 GHz)

Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point. Dx10/Dx20/Dx00A-AT 4-6 GHz differential probes are a general purpose probing solution with high input dynamic range and offset.
Differential Probes (4-6 GHz)

Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point. Dx10/Dx20/Dx00A-AT 4-6 GHz differential probes are a general purpose probing solution with high input dynamic range and offset.

Overview

Key Features
  • Choice of 4-6 GHz bandwidth models
  • Up to 5 Vpk-pk dynamic range with low noise
  • ±3 V offset range
  • Probe System (-PS models) provide complete capability
  • Ideal for DDR2, DDR3, LPDDR2
  • Deluxe soft carrying case
  • Wide variety of tips and leads
  • Solder-In Lead
  • Positioner (Browser) Tip
  • Adjustable (Browser) Tip
  • Square Pin Lead
  • HiTemp Solder-In Lead
WaveLink 4-6 GHz Probes
Teledyne LeCroy's WaveLink 4-6 GHz Differential Probes are a general purpose probing solution with high input dynamic range and offset.
Complete Probe System
A value-priced, comprehensive bundle of all items including differential amplifier, solder-in tip, quick connect tip, square pin tip, and positioner (browser) tip, platform/cable assembly, assorted interconnect parts, mounting devices, and other accessories, and a deluxe soft carrying case to hold all items. This makes selection as easy as simply choosing the bandwidth that you require.
High Dynamic Range and Offset
The combination of bandwidth, high input dynamic range and large offset range make the Dx10 & Dx20 ideal for DDR applications.
Deluxe Soft Carrying Case
A deluxe soft carrying case conveniently holds all components of the probe system.
Wide Variety of Tips
Support for solder-in, positioner (browser) tip, quick connect, square pin, and HiTemp solder-in leads allows for flexibility when making connections.
Adjustable Browser Tip
The Adjustable Tip Module, Dx00A-AT, with two highly flexible NiTiNOL alloy tips, allows for easy probing of very dense circuitry.

Differential Probes (8-13 GHz)

Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point. Dxx30 8-13 GHz differential probes medium bandwidth, general purpose probing solution with high input dynamic range and offset.
Differential Probes (8-13 GHz)

Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point. Dxx30 8-13 GHz differential probes medium bandwidth, general purpose probing solution with high input dynamic range and offset.

Overview

Key Features
  • Choice of 8, 10, or 13 GHz bandwidth models
  • 3.5 Vpk-pk dynamic range
  • ±4 V offset range
  • Probe System (-PS models) provide complete capability
  • Ideal for DDR3, DDR4, LPDDR3
  • Deluxe soft carrying case
  • Wide variety of tips and leads
    • Solder-In Lead
    • Positioner (Browser) Tip
    • SMA/SMP Lead
    • Square Pin Lead
  • SMA/SMP lead set accessory does not require purchase of a different amplifier
WaveLink Medium Bandwidth (8-13) GHz Probes
Teledyne LeCroy’s WaveLink 8-13 GHz Differential Probes are a medium bandwidth, general purpose probing solution with high input dynamic range and offset.
Complete Probe System
A value-priced, comprehensive bundle of all items including differential amplifier, solder-in tips (qty. 2), square pin tip, and positioner (browser) tip, platform/cable assembly, assorted interconnect parts, mounting devices, and other accessories, and a deluxe soft carrying case to hold all items. This makes selection as easy as simply choosing the bandwidth that you require.
High Dynamic Range and Offset
The combination of bandwidth, high input dynamic range and large offset range make the Dxx30 ideal for all DDR applications.
Deluxe Soft Carrying Case
A deluxe soft carrying case conveniently holds all components of the probe system.
Wide Variety of Tips
Support for solder-in, browser, square pin, and SMA/SMP cabled tip/lead connections allows for flexibility when making connections.
SMA/SMP Lead Set
The Dxx30 SMA/SMP lead set serves as a interconnection between the Dxx30 probe amplifier and SMA/SMP connectors.

Differential Probes (13-25 GHz)

Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point. Dxx05-A 13-25 GHz differential probes are the highest bandwith with high performance, large dynamic and offset range, and very low noise.
Differential Probes (13-25 GHz)

Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point. Dxx05-A 13-25 GHz differential probes are the highest bandwith with high performance, large dynamic and offset range, and very low noise.

Overview

Key Features
  • Choice of 13, 16, 20 and 25 GHz bandwidth models
    • Bandwidth rating is for probe + oscilloscope combined
    • Optimized probe + oscilloscope performance, automatically
  • 2.0Vpk-pk dynamic range
  • ±2.5V offset range
  • Probe System (-PS models) provide complete capability
  • Deluxe soft carrying case
  • Long-length solder-in tip with field replaceable resistors
  • Carbon-composite browser tips optimize signal fidelity and loading
  • Superior probe impedance for minimized loading
  • Probe noise as low as 14 nV/√Hz
WaveLink High Bandwidth (13-25) GHz Differential Probes
Teledyne LeCroy's WaveLink 13-25 GHz Differential Probes are a high bandwidth, high performance probe solution with large dynamic and offset range and very low noise
Complete Probe System
A value-priced, comprehensive bundle of all items including differential amplifier, solder-in tips (qty. 2) and positioner (browser) tip (qty. 1), platform/cable assembly, assorted interconnect parts, mounting devices, and other accessories, and a deluxe soft carrying case to hold all items. This makes selection as easy as simply choosing the bandwidth that you require.
High Dynamic Range and Offset
Exceptionally high dynamic range (2.0Vpk-pk) at high bandwidths (up to 25 GHz) and large offset capability as well.
Deluxe Soft Carrying Case
A deluxe soft carrying case conveniently holds all components of the probe system
High-Performance Solder-in Tip
Long-length solder-in tip with field replaceable resistors. External tip resistors locate the tip resistance as close to the point of contact as possible to minimize circuit loading.
Carbon-composite Browser Tips Maximize Signal Fidelity
Carbon fiber composite pogo-pin resistive tips used in the positioner tip locate an ideal distributed resistance at the point of contact. This design is unique to Teledyne LeCroy and provides improved signal fidelity.
Superior Probe Impedance
Circuit and signal loading is reduced by more than 50% compared to other high bandwidth probes. This greatly reduces measurement impact.

High Voltage Differential Probes

Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point.
High Voltage Differential Probes

Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point.

Products

High Voltage Differential Probes
  • AP031 - 700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100)
  • ADP300 - 1,400 V, 20 MHz High-Voltage Differential Probe
  • ADP305 - 1,400 V, 100 MHz High-Voltage Differential Probe
  • HVD3102 - 25 MHz High Voltage Differential Probe
  • HVD3106 - 120 MHz High Voltage Differential Probe
  • HVD3106-6M - 80 MHz High Voltage Differential Probe with 6m cable

High Voltage Probes

High voltage probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are several fixed-attenuation probes covering a range from 1 kV to 6 kV and varying transient overvoltage ratings. All of these high voltage probes feature a spring loaded probe tip and a variety of standard accessories to make probing high voltages safe and easy. Additionally, all of the high voltage probe have a probe sense pin to automatically configure the oscilloscope for use with the probe.
High Voltage Probes

High voltage probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are several fixed-attenuation probes covering a range from 1 kV to 6 kV and varying transient overvoltage ratings. All of these high voltage probes feature a spring loaded probe tip and a variety of standard accessories to make probing high voltages safe and easy. Additionally, all of the high voltage probe have a probe sense pin to automatically configure the oscilloscope for use with the probe.

Products

High Voltage Probes
  • HVP120 - 400 MHz, 1kV Vrms High-Voltage Passive Probe
  • PPE1.2KV - 10:1/100:1 200/300 MHz 50 MOhms High-Voltage Probe 600V/1.2kV Max. Volt. DC Limited Availability
  • PPE2KV - 100:1 400 MHz 50 MOhms High-Voltage Probe Limited Availability
  • PPE4KV - 100:1 400 MHz 50 MOhms High-Voltage Probe
  • PPE5KV - 100:1 400 MHz 50 MOhms High-Voltage Probe
  • PPE6KV - 1000:1 400 MHz 5 MOhms/50 MOhms High-Voltage Probe

Optical Probes

Teledyne LeCroy's wide-band multi-mode optical-to-electrical converters are designed for measuring optical communications signals. Their broad wavelength range and multi-mode input optics make these devices ideal for applications including Ethernet, Fibre Channel, and ITU telecom standards. Available to support optical data rates up to 11.3 Gb/s with reference receivers, or slightly higher without reference receivers.
Optical Probes

Teledyne LeCroy's wide-band multi-mode optical-to-electrical converters are designed for measuring optical communications signals. Their broad wavelength range and multi-mode input optics make these devices ideal for applications including Ethernet, Fibre Channel, and ITU telecom standards. Available to support optical data rates up to 11.3 Gb/s with reference receivers, or slightly higher without reference receivers.

Overview

These wide- band multi-mode optical-to-electrical converters are designed for measuring optical communications signals. They connect to Teledyne LeCroy real-time oscilloscopes and provide capability for physical layer signal assessment using a variety of oscilloscope tools, such as SDAIII-CompleteLinQ Serial Data Eye, Jitter, Noise and Crosstalk Analysis, mask testing, serial triggering and decoding, and other compliance and debug tools. Maximum data rate test capability is >11.317 Gb/s with reference receiver, or 12.5 Gb/s without.

Passive Probes

Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
Passive Probes

Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.

Overview

Passive Probes
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.

Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

 

Model Bandwidth Input R Input C Attenuation Maximum Voltage Diameter Recommended Oscilloscope
PP005A 500 MHz 10 MΩ 11 pF 10:01 500 V 5 mm 1,2,12, 13
PP006A 500 MHz 10 MΩ 12 pF 10:01 600 V 5 mm 3, 11
PP007-WS 500 MHz 10 MΩ 9.5 pF 10:01 400 V 2.5 mm 4
PP007-WR 500 MHz 10 MΩ 9.5 pF 10:01 400 V 2.5 mm 5, 7, 9, 15, 16
PP008 500 MHz 10 MΩ 9.5 pF 10:01 400 V 2.5 mm 4, 6, 8, 17
PP009 500 MHz 10 MΩ 9.5 pF 10:01 400 V 5 mm 4, 6, 8, 17
PP010 200 MHz 10 MΩ 12.5 pF 10:01 600 V 5 mm 10
PP011 500 MHz 10 MΩ 9.5 pF 10:01 400 V 5 mm 5, 7, 9, 15, 16
PP016 300 MHz/10 MHz 10 MΩ/1 MΩ 12 pF/46 pF 10:1/1:1 600 V 5 mm 14
PP017 200 MHz 10 MΩ 12 pF 10:01 600 V 5 mm 18
PP018 500 MHz 10 MΩ 10 pF 10:01 600 V 5 mm 18, 19
PP019 200 MHz 10 MΩ 12 pF 10:01 500 V 5 mm 20
PP020 500 MHz 10 MΩ 11 pF 10:01 500 V 5 mm 20

 

Recommended Oscilloscope
19300 Series11WaveJet(A) Series (= 350 MHz)
2LC Series12WavePro 900 Series
3LT Series13WavePro 7000 Series
4WaveSurfer 400 Series14WaveAce Series (200 MHz)
5WaveRunner 6000(A) Series15WavePro 7 Zi(A) Series
6WaveRunner Xi(A) Series (= 600 MHz)16WaveMaster 8 Zi(A) Series
7WaveRunner Xi(A) (1 GHz - 2 GHz)17WaveRunner 6 Zi Series
8WaveSurfer Xs(A,B) Series (= 600 MHz)18HDO4000 Series (200 MHz)
9WaveSurfer Xs(A,B) Series (1 GHz)19All HDO Series (>=350 MHz)
10WaveJet(A) Series (= 200 MHz)20WaveSurfer 3000 Series

Probe Parts and Kits

There are a variety of replacement and additional probe parts, tips and accessories.
Probe Parts and Kits

There are a variety of replacement and additional probe parts, tips and accessories

Products

Probe Parts and Kits
PK1-5MM-125 - Solid Tip 0.8 mm
PK1-5MM-126 - Spring Tip 0.8 mm
PK1-5MM-127 - BNC adapter 5.0-L
PK1-5MM-128 - Insulating cap 5.0-L
PK1-5MM-129 - Protection Cap 5.0-L
PK1-5MM-130 - Sprung hook 5.0-L
PK1-5MM-131 - Adjustment tool
PK1-5MM-132 - Flexible adapter 5.0-L to 4 mm
PK1-5MM-133 - Safety alligator clip red
PK1-5MM-134 - Ground Lead 22mm
AP-1M - 1 MOhm Adapter for WaveMaster
CALKIT-OSL - 3.5 mm Coaxial Calibration Kit (includes Open, Short, and 50 ohm reference standards)
Dx10-HiTEMP - WaveLink Temperature Extension cables for Dx10. Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set
PK-HV-002 - PK-HV-002
PK-HV-001 - Accessory kit for High Voltage Differential Probe
PK-HVA-01 - Replacement Alligator Clips for High Voltage Differential Probe
PK-HVA-02 - Replacement Pincer Clips for High Voltage Differential Probe
PK-HVA-03 - Replacement Hook Clips for High Voltage Differential Probe
PK-HVA-04 - Replacement Long Alligator Clips for High Voltage Differential Probe
PK-HVA-05 - Replacement Spade Terminals for High Voltage Differential Probe
Dx10-SI-HiTEMP - Replacement Solder tip leadset for use with D410/D610 and temperature extension cables
Dx20-HiTEMP - WaveLink Temperature Extension cables for Dx20. Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set
Dx20-SI-HiTEMP - Replacement Solder tip leadset for use with D420/620 and temperature extension cables
Dxx0-Cable-HiTemp - Replacement 30" matched cable set for use with HiTemp Solder tip leadset
L2.92A-PBUS - 2.92mm to ProBus Adapter with Probe Power and Communication Pass Through
L2.92A-PLINK - 2.92mm to ProLink Adapter with Probe Power and Communication Pass Through
LPA-BNC-KIT - Kit of 4 ProLink BNC Adapters with Case
LPA-K-A - Pro-Link to K/2.92mm Adapter
LPA-K-KIT-A - Kit of Qty. 4 Pro-Link to K/2.92mm Adapter
LPA-SMA-A - Pro-Link to SMA Adapter, new style
LPA-SMA-KIT-A - Kit of Pro-Link to SMA Adapter, new style
ME-15 - 1.5 Meter Module Extender Cable Limited Availability
OE695G-REFCAL - OE695G Reference Cal (1ch)
PACC-CD007 - Solder-In Ground (Qty. 2)
PACC-CD008 - Bendable Pogo Ground (qty of 2)
PACC-CD009 - Flexible IC Ground
PACC-CL001 - Probe Clips For SMD 0.5MM
PACC-LD001 - Ground Spring Hook
PACC-LD002 - Square Pin Ground Spring
PACC-LD003 - Replacement Right Angle S-Lead
PACC-LD004 - Replacement Right Angle L-Lead
PACC-LD006 - Single Lead 4.25
PACC-MS002 - Replacement Cartridge HFP Probe
PACC-MS003 - Low C Fixed Tip Cartridge
PACC-PT001 - Probe Tips Straight
PACC-PT002 - Probe Tips Sharp
PACC-PT003 - IC Lead Tip (Qty. 4)
PACC-PT004 - Discrete SMD Tip (Qty. 4)
PACC-PT005 - Bent Sharp Tip (Qty. 4)
PACC-ZD001 - Y lead Adapter for ZD differential probes - Qty 1
PACC-ZD002 - Solder-in lead for ZD differential probe - QTY 2
PACC-ZD003 - Long spring ground for ZD differential probe - QTY 2
PACC-ZD004 - Tip saver for ZD differential probe - QTY 2
PACC-ZD005 - Swivel tip adapter for ZD differential probe - QTY 1
PACC-ZD006 - Small IC adapter for ZD differential probe - QTY 2
PACC-ZD007 - Replacement Accessory kit for ZD200
PACC-ZD008 - Y-Lead Adapter
PACC-ZD009 - Micro pogo pin tips for ZD differential probe Qty 6
PK-ZS - Replacement Accessory Kit for ZS Series Active Probes
PK-ZS-001 - Straight Probe Tip (pkg of 4)
PK-ZS-002 - Offset Ground (pkg of 4)
PK-ZS-003 - Short Ground Lead (pkg of 4)
PK-ZS-004 - Long Ground Lead (pkg of 4)
PK-ZS-005 - Y Lead Adaptor (qty 4)
PK-ZS-006 - Right-Angle Connector (qty 4)
PK-ZS-007B - Sprung Hook - Black (qty 4)
PK-ZS-007R - Sprung Hook - Red (qty 4)
PK-ZS-008 - Ground Blade (qty 4)
PK-ZS-009 - Copper Pad (qty 4)
PK-ZS-010 - Color Coding Rings (4 Sets)
PK-ZS-014 - Y Lead Adaptor - ZS4000 (Qty.4)
PK-ZS-015 - Ground Blade (wide) - ZS4000 (Qty.4)
PK-ZS-016 - Offset Ground - ZS4000 (Qty.4)
PK-ZS-017 - Pogo Tip - ZS4000 (Qty.4)
PK-ZS-018 - 2.54mm Sq.Pin Adaptor - ZS4000 (Qty.4)
PK-ZS-019 - Freehand Probe Holder - ZS4000 (Qty.1)
PK-ZS-020 - Pogo Ground Lead - ZS4000 (Qty.4)
PK-ZS-021 - Ground Blade (narrow) - ZS4000 (Qty.4)
PK-ZS-022 - Straight Pin (short) - ZS4000 (Qty.4)
PK001 - Probe Accessories for PP001/PP002
PK-ZS-023 - Straight Pin (long) - ZS4000 (Qty.4)
PK-ZS-024 - 2.54mm PCB Adapter - ZS4000 (Qty.10)
PK-ZS-025 - Quad Flat Pack IC Clip Pair (Yellow/Green) (Qty.1 Pair)
PK-ZS4000 - ZS4000 Standard Accessory Pack
PK003 - Probe Accessories for PP061/PP062/PP064
PK006 - SMT Probing Accessories for AP020, PP002, and PP006 Surface Mount Technology Accessories
PK006-1 - Replacement Dual Lead Adapter
PK006-2 - Replacement Single Lead Adapter
PK006-3 - Replacement .05MM Clip Set
PK007-001 - Replacement Sprung Hook
PK007-002 - Replacement Standard GND
PK007-003 - Replacement Adjustment Tool
PK007-004 - Replacement Rigid Tip
PK007-005 - Replacement Spring Tip
PK007-006 - Replacement Color Coding Rings pack of 8
PK007-007 - Replacement Insulate Cap pack of 10
PK007-008 - Replacement IC-Cap for .5mm pack of 10
PK007-009 - Replacement IC-Cap for .65mm pack 10
PK007-010 - Replacement IC Cap for .8mm pack of 10
PK007-011 - Replacement IC-Cap for 1. mm pack 10
PK007-012 - Replacement IC-Cap for 1.27mm
PK007-013 - Replacement Ground Blade pack of 5
PK007-014 - Replacement Copper Pad pack of 25
PK007-015 - Replacement PCB Adaptor pack of 25
PK007-016 - Replacement Ground Spring
PK007-017 - Replacement Single Lead
PK007-018 - Replacement 2 Lead Adapter
PK007-019 - Replacement Pico Hook
PK007-020 - Replacement Micro Clip Long
PK007-021 - Replacement Micro Clip Short
PK007-022 - Replacement Adapter 2mm Plug
PK007-023 - Replacement Adapter 4mm Plug
PK007-024 - Replacement Ground Lead 0.8mm Socket
PK007-025 - Replacement Ground Lead with Clip
PK007-026 - Replacement Ground Lead with Mini Clip
PK007-027 - Replacement Ground Lead 0.8mm Socket
PK007-028 - Replacement Ground Lead 2mm Plug
PK007-029 - Replacement Ground Lead 4mm Plug
PK007-030 - Replacement HF-Comp Ground Lead
PK007-031 - Replacement BNC-Adapter 2.5
PK033 - Probe Accessories for AP033/AP034
PK101 - Microclip Accessories for PP005/PP005A
PK102 - Probe Accessories for PP005/PP005A
PK103 - Accessory Kit for PPE1.2kV, PPE2kV, PPE4kV, PPE5kV, and PPE6kV
pk104 - Accessory Kit for PPE20kV
PK104-1 - Ground Lead 15CM PPE20KV
PK104-2 - Hook For PPE20KV (PK104)
PK106 - SMT Probing Accessories for PPE Series, PP005/PP005A, and PP065 Surface Mount Technology Products
PK106-1 - Dual Lead Adapter PP005/PPE
PK106-2 - Single Lead Adapter PP005/PPE
PK106-3 - 0.5MM Clip PP005/PPE Green
PK106-4 - Probe Tip TO Pcb Adapter
PK106-5 - M/F Long Lead PP005/PPE
PK106-6 - M/F Short Lead PP005/PPE
PK106-8 - 0.5MM Clip PP005/PPE Yellow
PK111 - Replacement Accessory kit for ZD500, ZD1000, and ZD1500
PK116 - Probe Accessories Kit for PP006/PP006A
PK116-1 - Replacement PP006 Sprung Hook
PK116-2 - Replacement PP006 Ground Lead
PK116-3 - Replacement PP006 Ground Pin
PK30X-1 - Banana Hook Clips, (1 red and 1 blue)
PK30X-2 - Banana Alligator Clips, (1 red and 1 blue)
PK30X-3 - Banana Jaw Clips, (1 red and 1 blue)
PK30X-4 - Banana Clamp Clips, (1 red and 1 blue)
PK30X-5 - Banana Spade Terminals, (1 red and 1 blue)
PK350ST-1 - Replacement Damping Resistor Kit for D350ST-SI
PK500PT-1 - Replacement Probe Tip for D500PT, Pkg. of 2
PK600ST-1 - Replacement Resistor Kit for D600ST-SI (qty 5)
PK600ST-2 - Replacement Resistor Kit for D600ST-QC Quantity 20, 56 Ohm
PK701 - Basic Adapter Kit for PP007-WR-1 and PP007-WS-1
PK702 - Advanced Adapter Kit for PP007-WR-1 and PP007-WS-1
PK703 - SMD Adapter Kit for PP007-WR-1 and PP007-WS-1
PK704 - Microclip Adapter Kit for PP007-WR-1 and PP007-WS-1
PKIT4-5MM-101 - Standard Accessory Replacement Kit for PP017/PP018
PP001/002-1 - PP001/002 Ground Lead
PP001/002-2 - PP001/002 Probe Tip To BNC
PP001/002-3 - PP001/002 Sprung Hook
PP005-BNC - Replacement Probe Tip-BNC Adapter
PP005-GL11 - Replacement 11cm Ground Lead
PP005-GL22 - Replacement 22cm Ground Lead
PP005-GLPT - Replacement Probe Tip Ground Lead
PP005-HOOK - Replacement Sprung Hook
PP005-RT - Replacement Rigid Tip V2A
PP005-ST38 - Replacement Spring Tip .38MM
PP005-ST8 - Replacement Spring Tip .8MM
405400003 - Probe Offset Pin

Transmission Line Probes

Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ohm). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance. While they have lower DC input resistance than a traditional passive probe (usually 500 Ohm) to 5 kOhm), the input impedance of these probes remains nearly constant over their entire frequency range. A traditional /10 passive probe will have a 10 MOhm) input impedance at DC, however this impedance drops rapidly with frequency, passing below the input impedance....

Transmission Line Probes

Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ohm). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance. While they have lower DC input resistance than a traditional passive probe (usually 500 Ohm) to 5 kOhm), the input impedance of these probes remains nearly constant over their entire frequency range. A traditional /10 passive probe will have a 10 MOhm) input impedance at DC, however this impedance drops rapidly with frequency, passing below the input impedance of a transmission line probe at less than 100 MHz.

Overview

Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ω). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance. While they have lower DC input resistance than a traditional passive probe (usually 500 Ω to 5 k Ω), the input impedance of these probes remains nearly constant over their entire frequency range. A traditional ÷10 passive probe will have a 10 MW input impedance at DC, however this impedance drops rapidly with frequency, passing below the input impedance of a transmission line probe at less than 100 MHz.

In some applications, transmission line probes offer advantages over active probes. In addition to being less expensive, their passive design is more robust to over voltage and ESD exposure. They are useful in applications producing fast rising, narrow pulses with amplitudes which exceed the dynamic range of active probes. They also tend to have less parasitic effects on frequency response. A high BW transmission line probe driving a sampling oscilloscope can be used as a "golden standard" in situations when the response of an active probe measurement is questioned.